Supercritical steam generator

A supercritical steam generator is a type of boiler that operates at supercritical pressure, frequently used in the production of electric power.

In contrast to a subcritical boiler in which bubbles can form, a supercritical steam generator operates at pressures above the critical pressure3,200 psi or 22 MPa. Therefore, liquid water immediately becomes steam. Water passes below the critical point as it does work in a high pressure turbine and enters the generator's condenser, resulting in slightly less fuel use and therefore less greenhouse gas production.

Technically, the term "boiler" should not be used for a supercritical pressure steam generator as no "boiling" actually occurs in the device.

History of supercritical steam generation

Contemporary supercritical steam generators are sometimes refer as Benson boilers. In 1922, Mark Benson was granted a patent for a boiler designed to convert water into steam at high pressure.

Safety was the main concern behind Benson’s concept. Earlier steam generators were designed for relatively low pressures of up to about 100 bar (10 MPa; 1,450 psi), corresponding to the state of the art in steam turbine development at the time. One of their distinguishing technical characteristics was the riveted water/steam separator drum. These drums were where the water filled tubes were terminated after having passed through the boiler furnace.

These header drums were intended to be partially filled with water and above the water there was a baffle filled space where the boiler's steam and water vapour collected. The entrained water droplets were collected by the baffles and returned to the water pan. The mostly dry steam was piped out of the drum as the separated steam output of the boiler. These drums were often the source of boiler explosions, usually with catastrophic consequences.

However, this drum could be completely eliminated if the evaporation separation process was avoided altogether. This would happen if water entered the boiler at a pressure above the critical pressure (3,206 pounds per square inch, 22.10 MPa); was heated to a temperature above the critical temperature (706 °F, 374 °C) and then expanded (through a simple nozzle) to dry steam at some lower subcritical pressure. This could be obtained at a throttle valve located downstream of the evaporator section of the boiler.

As development of Benson technology continued, boiler design soon moved away from the original concept introduced by Mark Benson. In 1929, a test boiler that had been built in 1927 began operating in the thermal power plant at Gartenfeld in Berlin for the first time in subcritical mode with a fully open throttle valve. The second Benson boiler began operation in 1930 without a pressurizing valve at pressures between 40 and 180 bar (4 and 18 MPa; 580 and 2,611 psi) at the Berlin cable factory. This application represented the birth of the modern variable-pressure Benson boiler. After that development, the original patent was no longer used. The "Benson boiler" name, however, was retained.

Two current innovations have a good chance of winning acceptance in the competitive market for once-through steam generators:

On 3 June 2014, the Australian government's research organization CSIRO announced that they had generated 'supercritical steam' at a pressure of 23.5 MPa (3,410 psi) and 570 °C (1,060 °F) in what it claims is a world record for solar thermal energy.[1]

See also

Notes

  1. Jeffrey, Colin (June 3, 2014). "CSIRO sets world record in generating "supercritical" steam using solar power". gizmag.com. Retrieved 2014-06-09.