EDELWEISS

For other uses, see Edelweiss (disambiguation).
The EDELWEISS logo

EDELWEISS ( Expérience pour DEtecter Les WIMPs En Site Souterrain) is a dark matter search experiment located at the Modane Underground Laboratory in France. The experiment uses cryogenic detectors, measuring both the phonon and ionization signals produced by particle interactions in germanium crystals. This technique allows nuclear recoils events to be distinguished from electron recoil events.

The EURECA project is a proposed future dark matter experiment, which will involve researchers from EDELWEISS and the CRESST dark matter search.

Dark matter

Main article: dark matter

Dark matter is material which does not emit or absorb light. Measurements of the rotation curves of spiral galaxies suggest it makes up the majority of the mass of galaxies; and precision measurements of the cosmic microwave background radiation suggest it accounts for a significant fraction of the density of the Universe.

A possible explanation of dark matter comes from particle physics. WIMP (Weakly Interacting Massive Particle) is a general term for hypothetical particles which interact only through the weak nuclear and gravitational force. This theory suggests our galaxy is surrounded by a dark halo of such particles. EDELWEISS is one of a number of dark matter search experiments aiming to directly detect WIMP dark matter, by detecting the elastic scattering of a WIMP off an atom within a particle detector. As the interaction rate is so low, this requires sensitive detectors, good background discrimination, and a deep underground site (to reduce the background from cosmic rays).

Experiment

EDELWEISS is located in the Modane underground laboratory, in the Fréjus road tunnel between France and Italy, below 1800m of rock. A 20 cm lead shield reduces the gamma background, and a polyethylene shield reduces the neutron flux. All materials close to the detectors are screened for radiopurity. A dilution refrigerator is used to cool the detectors, built in the opposite orientation to most instruments with the detectors at the top and the refrigeration mechanism below.

EDELWEISS uses high purity germanium cryogenic bolometers cooled to 20 milliKelvin above absolute zero. The phonon and ionization signals produced by a particle interaction are measured. This allows background events to be rejected as nuclear recoils events (produced by WIMP or neutron interactions) produce much less ionization than electron recoil events (produced by alpha, beta and gamma radiation). The detectors are similar to those used by the CDMS experiment. Simultaneous detection of ionization and heat with semiconductors at low temperature was an original idea by Lawrence M. Krauss, Mark Srednicki and Frank Wilczek.[1]

A major limitation of early detectors was the problem of surface events. Due to incomplete charge collection, a particle interaction near the surface of the crystal gave no ionization signal, so electron recoils near the surface could be mistaken for nuclear recoils. To avoid this, the collaboration developed new detectors with interdigitised electrodes. Different voltages are applied to a series of electrodes so the direction of electric field is different near the surface of the crystal, allowing over 99.5% of surface events to be rejected.[2]

Results

Fig A. EDELWEISS I results. With CDMS parameter space excluded as of 2004. DAMA result is located in green area and is disallowed.

The results from the first phase of the experiment (EDELWEISS I) were published in 2005, excluding WIMP dark matter with an interaction cross-section above ≈10−6 pb (at ≈85 GeV).[3]:Fig 15

EDELWEISS-II ran 2009–10 with 4 kg of detectors (for a total effective exposure of 384 kg·d)[4] limiting high mass[4]:Fig 5 and low mass WIMPs,[5] and axions.[6] A cross-section of 4.4×10−8 pb is excluded at 90% C.L. for WIMP mass of 85 GeV. (Just above projected CDMS results in Fig A.)

Future

EDELWEISS-III, under construction, will have 40 detectors.[6] EURECA design work will continue as EDELWEISS-III runs into 2015, operating after 2017.

Collaboration

EDELWEISS is a collaboration of the following member institutions:

CEA – Commissariat à l'Énergie Atomique

CNRS – Centre National de la Recherche Scientifique

Institutions outside France

References

  1. Krauss, L.; Srednicki, M.; Wilczek, F. (1986). "Solar System Constraints and Signatures for Dark Matter Candidates". Physical Review D. 33 (8): 2079–2083. Bibcode:1986PhRvD..33.2079K. doi:10.1103/PhysRevD.33.2079.
  2. Juillard, A. (2008). "Status of the EDELWEISS-II Experiment". Journal of Low Temperature Physics. 151 (3–4): 806–811. Bibcode:2008JLTP..151..806J. doi:10.1007/s10909-008-9742-5.
  3. Sanglard, V.; et al. (EDELWEISS Collaboration) (2005). "Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors". Physical Review D. 71 (12): 122002. arXiv:astro-ph/0503265Freely accessible. Bibcode:2005PhRvD..71l2002S. doi:10.1103/PhysRevD.71.122002.
  4. 1 2 Armengaud, E.; et al. (EDELWEISS Collaboration) (2011). "Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes". Physics Letters B. 702 (5): 329–335. arXiv:1103.4070Freely accessible. Bibcode:2011PhLB..702..329E. doi:10.1016/j.physletb.2011.07.034.
  5. Armengaud, E.; et al. (EDELWEISS Collaboration) (2012). "A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors". Physical Review D. 86 (5): 051701. arXiv:1207.1815Freely accessible. Bibcode:2012PhRvD..86e1701A. doi:10.1103/PhysRevD.86.051701.
  6. 1 2 Armengaud, E.; et al. (EDELWEISS Collaboration) (2013). "Axion searches with the EDELWEISS-II experiment". Journal of Cosmology and Astroparticle Physics. 2013, (11): 067–067. arXiv:1307.1488Freely accessible. Bibcode:2013JCAP...11..067A. doi:10.1088/1475-7516/2013/11/067.

External links

This article is issued from Wikipedia - version of the 11/25/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.