Boiler explosion


A boiler explosion is a catastrophic failure of a boiler. As seen today, boiler explosions are of two kinds. One kind is a failure of the pressure parts of the steam and water sides. There can be many different causes, such as failure of the safety valve, corrosion of critical parts of the boiler, or low water level. Corrosion along the edges of lap joints was a common cause of early boiler explosions.

The second kind is a fuel/air explosion in the furnace, which would more properly be termed a firebox explosion. Firebox explosions in solid-fuel-fired boilers are rare, but firebox explosions in gas or oil-fired boilers are still a potential hazard.

Causes of boiler explosions

"The principal causes of explosions, in fact the only causes, are deficiency of strength in the shell or other parts of the boilers, over-pressure and over-heating. Deficiency of strength in steam boilers may be due to original defects, bad workmanship, deterioration from use or mismanagement."[1]

"Cause.-Boiler explosions are always due to the fact that some part of the boiler is, for some reason, too weak to withstand the pressure to which it is subjected. This may be due to one of two causes: Either the boiler is not strong enough to safely carry its proper working pressure, or else the pressure has been allowed to rise above the usual point by the sticking of the safety valves, or some similar cause"[2]


Boiler explosions are common in sinking ships once the superheated boiler touches cold sea water, as the sudden cooling of the superheated metal causes it to crack; for instance, when the SS Ben Lomond was torpedoed by a U-boat, the torpedoes and resulting boiler explosion caused the ship to go down in two minutes, leaving Poon Lim as the only survivor in a complement of 54 crew.[3][4]

Locomotive-type boiler explosions

Boiler explosions are of a particular danger in (locomotive-type) fire tube boilers because the top of the firebox (crown sheet) must be covered with some amount of water at all times; or the heat of the fire can weaken the crown sheet or crown stays to the point of failure, even at normal working pressure. Locomotive-type boilers have been used not only for locomotives, but also traction engines, portable engines, skid engines used for mining or logging, stationary engines for sawmills and factories, for heating, and as package boilers providing steam for other processes. In all applications, maintaining the proper water level is essential for safe operation.

Principle

Many shell-type boilers carry a large bath of liquid water which is heated beyond the boiling point of water at atmospheric pressure. During normal operation, the liquid water remains in the bottom of the boiler due to gravity, steam bubbles rise through the liquid water and collect at the top for use.

If this boiler opens up to the atmosphere, as a result of a break from over pressure or other such failure, the contents are allowed to expand suddenly into the atmosphere. The rapid release of steam and water can provide a very potent blast, and cause great damage to surrounding property or personnel. Since the water in the boiler is at a higher temperature and pressure (enthalpy) than boiling water would be at atmospheric pressure, some of this liquid will flash into vapor as the pressure drops by the rapid formation of steam bubbles throughout the water.

The energy of this expanding steam and water is now performing work just as it would have done in the engine, with a force that can peel back the material around the break, severely distorting the shape of the plate which was formerly held in place by stays, or self-supported by its original cylindrical shape.

The action of the rapidly expanding steam bubbles will also perform work by throwing large "slugs" of water inside the boiler. A fast-moving mass of water carries a great deal of energy (from the expanding steam), and in collision with the shell of the boiler results in a violent destructive effect. This can greatly enlarge the original rupture, or tear the shell in two.[5]

Many plumbers and steamfitters are aware of the phenomenon called "water hammer". A few ounce "slug" of water passing through a steam line and striking a 90 degree elbow can instantly fracture a fitting that is otherwise capable of handling several times the normal static pressure. It can then be understood that a few hundred, or even a few thousand pounds of water moving at the same velocity inside a boiler shell can easily blow out a tube sheet, collapse a firebox, even toss the entire boiler a surprising distance through reaction as the water exits the boiler, like the recoil of a heavy cannon firing a ball.

A steam locomotive operating at 350 psi (2.4 MPa) would have a temperature of about 225 °C, and a specific enthalpy of 963.7 kJ/kg.[6] Since standard pressure saturated water has a specific enthalpy of just 418.91 kJ/kg,[7] the difference between the two specific enthalpies, 544.8 kJ/kg, is the total energy expended in the explosion.

So in the case of a large locomotive which can hold as much as 10,000 kg of water at a high pressure and temperature state, this explosion would have an energy release equal to about 1160 kg of TNT.

Firebox explosions

In the case of a firebox explosion, these typically occur after a burner flameout. Oil fumes, natural gas, propane, coal, or any other fuel can build up inside the combustion chamber. This is especially of concern when the vessel is hot; the fuels will rapidly volatize due to the temperature. Once the lower explosive limit (LEL) is reached, any source of ignition will cause an explosion of the vapors.

A fuel explosion within the confines of the firebox may damage the pressurized boiler tubes and interior shell, potentially triggering structural failure, steam or water leakage, and/or a secondary boiler shell failure and steam explosion.

A common form of minor firebox "explosion" is known as "drumming" and can occur with any type of fuel. Instead of the normal "roar" of the fire, a rhythmic series of "thumps" and flashes of fire below the grate and through the firedoor indicate that the combustion of the fuel is proceeding through a rapid series of detonations, caused by an inappropriate air/fuel mixture with regard to the level of draft available. This usually causes no damage in locomotive type boilers, but can cause cracks in masonry boiler settings if allowed to continue.

Grooving

The plates of early locomotive boilers were joined by simple overlapping joints. This practice was satisfactory for the annular joints, running around the boiler, but in longitudinal joints, along the length of the boiler, the overlap of the plates diverted the boiler cross-section from its ideal circular shape. Under pressure the boiler strained to reach, as nearly as possible, the circular cross-section. Because the double-thickness overlap was stronger than the surrounding metal, the repeated bending and release caused by the variations in boiler pressure caused internal cracks, or grooves (deep pitting), along the length of the joint. The cracks offered a starting point for internal corrosion, which could hasten failure.[8] It was eventually found that this internal corrosion could be reduced by using plates of sufficient size so that no joints were situated below the water level.[9][10] Eventually the simple lap seam was replaced by the single or double butt-strap seams, which do not suffer from this defect.

Due to the constant expansion and contraction of the firebox a similar form of "stress corrosion" can take place at the ends of staybolts where they enter the firebox plates, and is accelerated by poor water quality. Often referred to as "necking", this type of corrosion can reduce the strength of the staybolts until they are incapable of supporting the firebox at normal pressure.

Grooving (deep, localized pitting) also occurs near the waterline, particularly in boilers that are fed with water that has not been de-aerated or treated with oxygen scavenging agents. All "natural" sources of water contain dissolved air, which is released as a gas when the water is heated. The air (which contains oxygen) collects in a layer near the surface of the water and greatly accelerates corrosion of the boiler plates in that area.[11]

Firebox

The intricate shape of a locomotive firebox, whether made of soft copper or of steel, can only resist the steam pressure on its internal walls if these are supported by stays attached to internal girders and the outer walls. They are liable to fail through fatigue (because the inner and outer walls expand at different rates under the heat of the fire), from corrosion, or from wasting as the heads of the stays exposed to the fire are burned away. If the stays fail the firebox will explode inwards. Regular visual inspection, internally and externally, is employed to prevent this.[9][12] Even a well-maintained firebox will fail explosively if the water level in the boiler is allowed to fall far enough to leave the top plate of the firebox uncovered.[13] This can occur when crossing the summit of the hill, as the water flows to the front part of the boiler and can expose the firebox crown sheet. The majority of locomotive explosions are firebox explosions caused by such crown sheet uncovering.[14]

Steamboat boilers

Steamboat explodes in Memphis, Tennessee in 1830

The Pennsylvania was a side wheeler steamboat which suffered a boiler explosion in the Mississippi River and sank at Ship Island near Memphis, Tennessee, on June 13, 1858. Of the 450 passengers on board more than 250 died, including Henry Clemens, the younger brother of the author Mark Twain.

SS Ada Hancock, a small steamboat used to transfer passengers and cargo to and from the large coastal steamships that stopped in San Pedro Harbor in the early 1860s, suffered disaster when its boiler exploded violently in San Pedro Bay, the port of Los Angeles, near Wilmington, California on April 27, 1863 killing twenty-six people and injuring many others of the fifty-three or more passengers on board.

The steamboat Sultana was destroyed in an explosion on 27 April 1865, resulting in the greatest maritime disaster in United States history. An estimated 1,700 passengers were killed when one of the ship's four boilers exploded and the Sultana sank not far from Memphis, Tennessee.

Another US Civil War Steamboat explosion was the Steamer Eclipse on January 27, 1865, which was carrying members of the 9th Indiana Artillery. One official Records report mentions the disaster reports 10 killed and 68 injured;[15] a later report mentions that 27 were killed and 78 wounded.[16] Fox's Regimental Losses reports 29 killed.[17][18]

Use of boilers

The stationary steam engines used to power machinery first came to prominence during the industrial revolution, and in the early days there were many boiler explosions from a variety of causes. One of the first investigators of the problem was William Fairbairn, who helped establish the first insurance company dealing with the losses such explosions could cause. He also established experimentally that the hoop stress in a cylindrical pressure vessel like a boiler was twice the longitudinal stress.[notes 1] Such investigations helped him and others explain the importance of stress concentrations in weakening boilers.

Modern boilers

Modern boilers are designed with redundant pumps, valves, water level monitors, fuel cutoffs, automated controls, and pressure relief valves. In addition, the construction must adhere to strict engineering guidelines set by the relevant authorities. The NBIC, ASME, and others attempt to ensure safe boiler designs by publishing detailed standards. The result is a boiler unit which is less prone to catastrophic accidents.

Also improving safety is the increasing use of "package boilers." These are boilers which are built at a factory then shipped out as a complete unit to the job site. These typically have better quality and fewer issues than boilers which are site assembled tube-by-tube. A package boiler only needs the final connections to be made (electrical, breaching, condensate lines, etc.) to complete the installation.

Steam explosions

In steam locomotive boilers, as knowledge was gained by trial and error in early days, the explosive situations and consequent damage due to explosions were inevitable. However, improved design and maintenance markedly reduced the number of boiler explosions by the end of the 19th century. Further improvements continued in the 20th century.

On land-based boilers, explosions of the pressure systems happened regularly in stationary steam boilers in the Victorian era, but are now very rare because of the various protections provided, and because of regular inspections compelled by governmental and industry requirements.

Water heaters can explode with surprising violence when their safety devices fail.

Reactor explosions

A steam explosion can occur in any kind of a water heater, where a sufficient amount of energy is delivered and the steam created exceeds the strength of the vessel. When the heat delivery is sufficiently rapid, a localized superheating can occur, resulting in a water hammer destroying the vessel. The SL-1 nuclear reactor accident is a good example.

Locomotive boiler explosions in the UK

Aftermath of a boiler explosion on a railway locomotive circa 1850.

Hewison (1983)[19] gives a comprehensive account of British boiler explosions, listing 137 between 1815 and 1962. It is noteworthy that 122 of these were in the 19th century and only 15 in the 20th century.

Boiler explosions generally fell into two categories. The first is the breakage of the boiler barrel itself, through weakness/damage or excessive internal pressure, resulting in sudden discharge of steam over a wide area. Stress corrosion cracking at the lap joints was a common cause of early boiler explosions, probably caused by caustic embrittlement. The water used in boilers was not often closely controlled, and if acidic, could corrode the wrought iron boiler plates. Galvanic corrosion was an additional problem where copper and iron were in contact. Boiler plates have been thrown up to a quarter of a mile (Hewison, Rolt). The second type is the collapse of the firebox under steam pressure from the adjoining boiler, releasing flames and hot gases into the cab. Improved design and maintenance almost totally eliminated the first type, but the second type is always possible if the engineer and fireman do not maintain the water level in the boiler.

Boiler barrels could explode if the internal pressure became too high. To prevent this, safety valves were installed to release the pressure at a set level. Early examples were spring-loaded, but John Ramsbottom invented a tamper-proof valve which was universally adopted. The other common cause of explosions was internal corrosion which weakened the boiler barrel so that it could not withstand normal operating pressure. In particular, grooves could occur along horizontal seams (lap joints) below water level. Dozens of explosions resulted, but were eliminated by 1900 by the adoption of butt joints, plus improved maintenance schedules and regular hydraulic testing.

Fireboxes were generally made of copper, though later locomotives had steel fireboxes. They were held to the outer part of the boiler by stays (numerous small supports). Parts of the firebox in contact with full steam pressure have to be kept covered with water, to stop them overheating and weakening. The usual cause of firebox collapses is that the boiler water level falls too low and the top of the firebox (crown sheet) becomes uncovered and overheats. This occurs if the fireman has failed to maintain water level or the level indicator (gauge glass) is faulty. A less common reason is breakage of large numbers of stays, due to corrosion or unsuitable material.

Throughout the 20th century, two boiler barrel failures and thirteen firebox collapses occurred in the UK. The boiler barrel failures occurred at Cardiff in 1909 and Buxton in 1921; both were caused by misassembly of the safety valves causing the boilers to exceed their design pressures. Of the 13 firebox collapses, four were due to broken stays, one to scale buildup on the firebox, and the rest were due to low water level.

See also

Notes

  1. Fairbairn's theoretical calculation assumes that the cylindrical vessel is much longer than its diameter. In practice, this is a viable approximation for any boiler that is a right cylinder or longer. Even for a short, squat boiler such as the Scotch, the reduced end area due to the tubes and their staying effect on the end-plates means that the principal stress is still this hoop stress.

Bibliography

References

  1. Roper, Stephen (1899). Roper's Engineer's Handy Book (15th edition) Philadelphia: David McKay (p.207–208)
  2. The Colliery Engineers Company (1900) Locomotive Boilers (I.C.S. Reference Library #59) Statione's Hall, London: International Textbook Company
  3. The Colliery Engineers Company (1900) Locomotive Boilers (I.C.S. Reference Library #59) Stationer's Hall, London: International Textbook Company (sec.12,p.76)
  4. Milo D. Koretsky, “Engineering and Chemical Thermodynamics”, John Wiley & Sons, 2004, p. 508
  5. Milo D. Koretsky, “Engineering and Chemical Thermodynamics”, John Wiley & Sons, 2004, p. 509
  6. Hewison (1983: 59 et sec)
  7. 1 2 Hewison (1983: 15)
  8. Baldwin, Thomas (1 October 1867). "On single and double riveted joints". Transactions for 1866. London: Society of Engineers: 150.
  9. Graham, Frank D. (1945) "Audel's Power Plant Engineers guide" New York, Ny: Theo Audel and Co. (p.332-333, figure 55: "corrosion along the water line due to air")
  10. Bell, A Morton (1950). Locomotives. 1. London: Virtue. pp. 20–23. OCLC 499543971.
  11. Staff (1957). "The Boiler: Boiler Mountings and Details". Handbook for railway steam locomotive enginemen. London: British Transport Commission. p. 53.
  12. http://www.homemodelenginemachinist.com/f19/small-model-boiler-explosion-video-4936/
  13. http://cdl.library.cornell.edu/cgi-bin/moa/pageviewer?frames=1&coll=moa&view=50&root=%2Fmoa%2Fwaro%2Fwaro0103%2F&tif=00622.TIF&cite=http%3A%2F%2Fcdl.library.cornell.edu%2Fcgi-bin%2Fmoa%2Fmoa-cgi%3Fnotisid%3DANU4519-0103
  14. http://cdl.library.cornell.edu/cgi-bin/moa/pageviewer?frames=1&coll=moa&view=50&root=%2Fmoa%2Fwaro%2Fwaro0109%2F&tif=00722.TIF&cite=http%3A%2F%2Fcdl.library.cornell.edu%2Fcgi-bin%2Fmoa%2Fmoa-cgi%3Fnotisid%3DANU4519-0109
  15. http://www.civilwarhome.com/chapt12.htm
  16. "9th Indiana Artillery History".
  17. Hewison, Locomotive Boiler Explosions

Further reading

External links

Wikimedia Commons has media related to Boiler explosions.
This article is issued from Wikipedia - version of the 12/3/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.